Does Bartlett Instrument manufacture standalone control boxes?
No. We don't currently sell standalone control boxes. To see a list of standalone control box distributors as well as a sample wiring diagram, click here .
What does a rate of "9999" mean?
When 9999 is used as a rate, that indicates a maximum ramp rate (either up or down) is being used.
How do I tell which type of thermocouple I am using with my controller?
There are some standard wire colors used with different types of thermocouples:
Type K thermocouples - red and yellow Type S thermocouples - red and black Type J thermocouples - red and white I can't find my manual for my controller. Can I get a new one from Bartlett Instrument Company?
One option is to download a printable manual from this page on our web site. Another option is to call us and order one to be sent to you. There is a nominal charge for this, however.
During programming of a firing, I typed the wrong number. How do I correct this?
Before pressing "ENTER", enter zero until all zeros are displayed, then enter the correct number. If you have already pressed "ENTER", you must press "ENTER"to progress through to the end of the program then start the program again.
I turned on the controller and 'FAIL' is displayed. What does this mean?
The thermocouple is not connected to the controller or has failed. When connecting the thermocouple, connect the red wire to the connector with a RED dot and connect the yellow wire to the connector with the YELLOW dot. On all thermocouples, the RED wire is always negative; the YELLOW wire in this case is the positive. Also there may be a break in one of the thermocouple lead wires, if so, the thermocouple must be replaced.
How can I find out the final temperature which was reached during a cone firing?
At the end of a cone firing, the current kiln temperature and 'CPLt' will be alternately flashing in the display. Press STOP. Then press Review Program, the final temperature will display. This final temperature will be retained until the next firing or until the controller is reprogrammed.
When starting a firing on the Genesis, what if I enter my start code but don't see the GO button to start the kiln?
If GO does not appear after you have entered the start code, you have typed in the incorrect start code. You can try re-entering the start code or you can change the controllers start code under MENU - CONFIGURATION - START CODE.
My kiln has a different manufacturer's controller on it and I'd like to replace it with a Bartlett. Is it compatible or do I need a special wiring harness?
It's possible that we will be able to build the controller with the appropriate connectors on it so no special wiring harness would be needed. Check with us to find out what we have available.
I see CN05 flashing when I review my program - what does that mean?
The information flashing is CNOS for Cone Offset. If you look at page 16 in the manual , it outlines the each key in the sequence displayed when you review a program.